Individual Drafting Details

Terms of Use:

These CAD details have been made available by New Zealand Steel Limited to help you design and build with steel framing. By downloading any of these CAD details (the Details) you (the User) accept they are for guidance only and not specific to any particular project. New Zealand Steel Limited makes no warranties, representations or undertakings of any kind (expressed or implied) with regard to the accuracy, adequacy, currency or completeness of the Details, or that the Details are suitable for any specific or intended use. While New Zealand Steel Limited has taken care in making these Details available, the User will remain solely responsible for the use of the Details and/or to anyone receiving or using systems created by the User. You should obtain specific architectural, engineering or other technical and/or professional advice to assess the suitability of the Details to your particular project. New Zealand Steel Limited accepts no liability arising out of the use, reproduction, or distribution of the Details. By downloading and using the Details you acknowledge and agree to the terms outlined herein. If you disagree with such terms please discontinue using the Details.

Please click on the format to download the file you require.

Detail Index

Detail Schedule

Detail Schedule

A1000

Thermal Breaks

Thermal Break - Cavity Fix (sheet inside underlay)

Thermal Break - Cavity Fix (sheet inside underlay)

A1015

Thermal Break - Cavity Fix (strips inside underlay)

Thermal Break - Cavity Fix (strips inside underlay)

A1014

Thermal Break - Direct Fix (strips outside underlay)

Thermal Break - Direct Fix (strips outside underlay)

A1013

Thermal Break - Direct Fix (sheet inside underlay)

Thermal Break - Direct Fix (sheet inside underlay)

A1012

Thermal Break - Direct Fix (strips inside underlay)

Thermal Break - Direct Fix (strips inside underlay)

A1011

Thermal Break Locations

Thermal Break Locations

A1010

Structural & Construction

Shower/Tub Wall Support

Shower/Tub Wall Support

A1140

Wiring and Piping

Wiring and Piping

A1130

Tiled Roof Cladding Soffit

Tiled Roof Cladding Soffit

A1120

Skillion Roof

Skillion Roof

A1110

Floor Slab to Wall. Hold Down 6kN Connection

Floor Slab to Wall. Hold Down 6kN Connection

A1053

Floor Slab to Wall. Hold Down 12kN Connection

Floor Slab to Wall. Hold Down 12kN Connection

A1052

Steel Cladding

Steel Cladding Vertical Profile - Meter Box - Direct Fix

Steel Cladding Vertical Profile - Meter Box - Direct Fix

A1255

Steel Cladding Horizontal Profile - Meter Box - Cavity Fix

Steel Cladding Horizontal Profile - Meter Box - Cavity Fix

A1250

Steel Cladding Vertical Profile - Head Opening - Direct Fix

Steel Cladding Vertical Profile - Head Opening - Direct Fix

A1245

Steel Cladding Horizontal Profile - Head Opening - Cavity Fix

Steel Cladding Horizontal Profile - Head Opening - Cavity Fix

A1240

Steel Cladding Vertical Profile - Jambs - Direct Fix

Steel Cladding Vertical Profile - Jambs - Direct Fix

A1235

Steel Cladding Horizontal Profile - Jambs - Cavity Fix

Steel Cladding Horizontal Profile - Jambs - Cavity Fix

A1230

Steel Cladding Vertical Profile - Sill Opening - Direct Fix

Steel Cladding Vertical Profile - Sill Opening - Direct Fix

A1225

Steel Cladding Horizontal Profile - Sill Opening - Cavity Fix

Steel Cladding Horizontal Profile - Sill Opening - Cavity Fix

A1220

Steel Cladding Vertical Profile - Wall to Base - Direct Fix

Steel Cladding Vertical Profile - Wall to Base - Direct Fix

A1215

Steel Cladding Horizontal Profile - Wall to Base - Cavity Fix

Steel Cladding Horizontal Profile - Wall to Base - Cavity Fix

A1210

Weatherboard Cladding

Weatherboard Cladding - External Corner - Cavity Fix

Weatherboard Cladding - External Corner - Cavity Fix

A1370

Weatherboard Cladding - Internal Corner - Cavity Fix

Weatherboard Cladding - Internal Corner - Cavity Fix

A1360

Weatherboard Cladding - Meter Box - Direct Fix

Weatherboard Cladding - Meter Box - Direct Fix

A1355

Weatherboard Cladding - Meter Box - Cavity Fix

Weatherboard Cladding - Meter Box - Cavity Fix

A1350

Weatherboard Cladding - Head Opening - Direct Fix

Weatherboard Cladding - Head Opening - Direct Fix

A1345

Weatherboard Cladding - Head Opening - Cavity Fix

Weatherboard Cladding - Head Opening - Cavity Fix

A1340

Weatherboard Cladding - Jambs - Direct Fix

Weatherboard Cladding - Jambs - Direct Fix

A1335

Weatherboard Cladding - Jambs - Cavity Fix

Weatherboard Cladding - Jambs - Cavity Fix

A1330

Weatherboard Cladding - Sill Opening - Direct Fix

Weatherboard Cladding - Sill Opening - Direct Fix

A1325

Weatherboard Cladding - Sill Opening - Cavity Fix

Weatherboard Cladding - Sill Opening - Cavity Fix

A1320

Weatherboard Cladding - Wall to Base - Direct Fix

Weatherboard Cladding - Wall to Base - Direct Fix

A1315

Weatherboard Cladding - Wall to Base - Cavity Fix

Weatherboard Cladding - Wall to Base - Cavity Fix

A1310

Sheet Cladding

Sheet Cladding - Meter Box - Direct Fix

Sheet Cladding - Meter Box - Direct Fix

A1455

Sheet Cladding - Meter Box - Cavity Fix

Sheet Cladding - Meter Box - Cavity Fix

A1450

Sheet Cladding - Jambs - Direct Fix

Sheet Cladding - Jambs - Direct Fix

A1445

Sheet Cladding - Jambs - Cavity Fix

Sheet Cladding - Jambs - Cavity Fix

A1440

Sheet Cladding - Head Lintel - Direct Fix

Sheet Cladding - Head Lintel - Direct Fix

A1436

Sheet Cladding - Head Opening - Direct Fix

Sheet Cladding - Head Opening - Direct Fix

A1435

Sheet Cladding - Head Opening - Cavity Fix

Sheet Cladding - Head Opening - Cavity Fix

A1430

Sheet Cladding - Sill Opening - Direct Fix

Sheet Cladding - Sill Opening - Direct Fix

A1425

Sheet Cladding - Sill Opening - Cavity Fix

Sheet Cladding - Sill Opening - Cavity Fix

A1420

Sheet Cladding - Wall to Base - Direct Fix

Sheet Cladding - Wall to Base - Direct Fix

A1415

Sheet Cladding - Wall to Base - Cavity Fix

Sheet Cladding - Wall to Base - Cavity Fix

A1410

Brick Cladding

Brick Cladding - Meter Box - Cavity Fix

Brick Cladding - Meter Box - Cavity Fix

A1550

Brick Cladding - Head Opening - Cavity Fix

Brick Cladding - Head Opening - Cavity Fix

A1540

Brick Cladding - Jambs - Cavity Fix

Brick Cladding - Jambs - Cavity Fix

A1530

Brick Cladding - Sill Opening - Cavity Fix

Brick Cladding - Sill Opening - Cavity Fix

A1520

Brick Cladding to Unprotected Ground - Wall to Base - Cavity Fix

Brick Cladding to Unprotected Ground - Wall to Base - Cavity Fix

A1511

Brick Cladding to Pavement - Wall to Base - Cavity Fix

Brick Cladding to Pavement - Wall to Base - Cavity Fix

A1510

AAC/EIFS Cladding

AAC / EIFS Cladding - Meter Box - Cavity Fix

AAC / EIFS Cladding - Meter Box - Cavity Fix

A1750

AAC / EIFS Cladding - Head Opening - Cavity Fix

AAC / EIFS Cladding - Head Opening - Cavity Fix

A1740

AAC / EIFS Cladding - Jambs - Cavity Fix

AAC / EIFS Cladding - Jambs - Cavity Fix

A1730

AAC / EIFS Cladding - Sill Opening - Cavity Fix

AAC / EIFS Cladding - Sill Opening - Cavity Fix

A1720

AAC / EIFS Cladding - Wall to Base - Cavity Fix

AAC / EIFS Cladding - Wall to Base - Cavity Fix

A1710